Cluster Mode FPolicy Definitions

In the commands below, replace the parameters with the required values:

[vserver_name]

The name of the vserver

[monitors server ip]

The ip address of the server where the Activity Monitor service is installed

[port number]

The port number configured in the Application configuration wizard in section 7

[volume names to include]

Replace with * if all volumes need to be monitored, or enter a list of volumes to monitor

[running number]

A sequential number of the policy in the policy hierarchy. If no FPolicy is defined, this should be 1.

To configure FPolicy for CIFS:

fpolicy policy event create -event-name siq_cifs_events -protocol cifs -file-operations create, create_dir, delete, delete_dir, read, write, rename, rename_dir, setattr, open -vserver [vserver_name] -filters first-read, first-write, open-with-delete-intent
fpolicy policy external-engine create -vserver [vserver_name] -engine-name siq_cifs_engine -primary-servers [monitors server ip] -port [port_number] -extern-engine-type asynchronous -ssl-option no-auth
fpolicy policy create -vserver [vserver_name] -policy-name wbx_cifs_policy -events siq_cifs_events -engine siq_cifs_engine -is-mandatory false 
fpolicy policy scope create -vserver [vserver_name] -policy-name wbx_cifs_policy -volumes-to-include [* or volume names to include]
fpolicy enable -vserver [vserver_name] -policy-name wbx_cifs_policy -sequence-number [running_number]

To configure FPolicy for NFS:

fpolicy policy event create -event-name siq_nfs3_events -protocol nfsv3 -file-operations create, create_dir, delete, delete_dir, read, write, rename, rename_dir, setattr -vserver [vserver_name]
fpolicy policy event create -event-name siq_nfs4_events -protocol nfsv4 -file-operations create, create_dir, delete, delete_dir, read, write, rename, rename_dir, setattr -vserver [vserver_name]
fpolicy policy external-engine create -vserver [vserver_name] -engine-name siq_nfs_engine -primary-servers [monitors server ip] -port [port_number] -extern-engine-type asynchronous -ssl-option no-auth
fpolicy policy create -vserver [vserver_name] -policy-name wbx_nfs_policy -events siq_nfs3_events, siq_nfs4_events -engine siq_nfs_engine -is-mandatory false -allow-privileged-access yes -privileged-user-name [domain\user_name]
fpolicy policy scope create -vserver [vserver_name] -policy-name wbx_nfs_policy -volumes-to-include [* or volume names to include]
fpolicy enable -vserver [vserver_name] -policy-name wbx_nfs_policy -sequence-number [running_number]

If multiple activity monitors are installed on the same server, set a unique port per vserver, and replace [port_number] with the value configured in the Application.